Infrastructure for facilities that can’t afford downtime.

Talk to our data center team

Mission-critical data center solutions designed for high availability, operational resilience and scale, from a single edge site to a hyperscale campus.

  • TIA-942
  • ASHRAE
  • IEC & SBC

(01) Overview

A data center is only as reliable as the systems underneath the racks. GamaOne handles those systems end to end: the power path that keeps servers running through an outage, the cooling that holds temperature under full load, and the controls that give your team visibility over all of it.

  • Standard

    TIA-942

    Global standard for data center telecommunications infrastructure.

  • Standard

    ASHRAE

    Thermal guidelines for mission-critical hardware environments.

  • Standard

    IEC & SBC

    Electrotechnical safety and structural resilience codes.

A data hall aisle between two rows of server racks with violet status lights, glass doors closing the cold aisle at the far end.

Data hall · cold aisle containment

(02) Scope

What we deliver

Four systems, designed and installed as one, from the utility feed to the rack.

01 / 04

Power systems

Redundant power from the utility feed to the rack: UPS systems, standby generators, switchgear and distribution to your target redundancy.

UPSGeneratorsSwitchgear
Redundancy
N+1 to 2N
Components
UPS · Generators · Switchgear
Standards
IEC & SBC

02 / 04

Cooling and thermal management

Cooling sized for your real heat load: CRAC and CRAH systems, in-row and liquid cooling, containment and airflow design that hold temperature under full load.

CRAC and CRAHIn-row and liquidContainment
Sized to
Real heat load
Components
CRAH · In-row · Containment
Standards
ASHRAE

03 / 04

Controls and monitoring

One view of the whole facility: BMS and DCIM integrated so your team sees power, temperature and capacity in real time, and is alerted before a problem becomes an outage.

BMSDCIMAlerts
Visibility
Real time
Systems
BMS · DCIM
Monitors
Power · Temperature · Capacity

04 / 04

Structured cabling and connectivity

The physical network layer, planned for growth: structured cabling, pathways and cross-connects, so adding capacity later is a patch, not a rebuild.

Structured cablingPathwaysCross-connects
Planned for
Growth
Components
Cabling · Pathways · Cross-connects
Standards
TIA-942

(03) Redundancy

Built to your redundancy target

N+1 for a regional site, 2N for a facility that has to ride through any single failure.

Fig. 02 · N, one pathFig. 02 · N+1, one path and a standby UPSFig. 02 · 2N, two independent paths
  • Utility feed
  • UPS, path A and B
  • Switchgear
  • Distribution to racks

(04) Process

How we work

One team from the first load study to years of operation.

  1. 01Drawing

    Design

    Load profile, redundancy target and site layout, modeled before the first pour.

  2. 02Site

    Build

    Power, cooling and controls installed in sequence with the civil works, on one schedule.

  3. 03Testing

    Commission

    Every system load-tested individually, then together, before the facility goes live.

  4. 04Lifecycle

    Operate

    Ongoing monitoring, maintenance and capacity planning as your load grows.

(05) Selected project

Delivering now

All projects
Fig. · DC 01 campus, illustrative
  • Power yard
  • Phase 1
  • Future phases

Client · DataVolt

Ongoing

16 MW

Data center DC 01, phase 1, Saudi Arabia

Scope
Execution and development of the MEP works
Sector
Data center
Delivered with
DamaGroup
Completion
2026
View project
Next capabilitySmart City SolutionsOne connected layer for the systems a city runs on.

Start a project

Strengthening the future
of smart infrastructure.

Tell us about your site, your load and your timeline, and the right engineering team will get back to you.